What Does Code B1985 Mean?
DTC B1985 indicates a specific electrical fault within the seat’s lumbar deflate circuit. This code is typically set by the Body Control Module (BCM) or a dedicated Seat Control Module (SCM), rather than the Engine Control Module (ECM) or Powertrain Control Module (PCM), as B-codes generally relate to body electrical systems. The module monitors the electrical integrity and operational state of the circuit responsible for deflating the lumbar support bladder or mechanism. When the module detects an open circuit, a short to ground, a short to voltage, or an out-of-range resistance value within the switch, its associated wiring, or the deflate actuator (solenoid or motor), it interprets this as a failure and sets code B1985. This directly impacts the ability of the seat’s lumbar support system to reduce pressure or retract the support, often resulting in the lumbar support remaining in an inflated or expanded state.
Common Symptoms
- Lumbar support remains inflated and cannot be deflated.
- The lumbar deflate function is completely inoperative.
- Audible click or whirring sound is absent when attempting to deflate the lumbar support.
- No discernible change in lumbar support pressure when the deflate switch is pressed.
- Dashboard or infotainment system warning light, if the vehicle is equipped with advanced occupant comfort system diagnostics.
What Causes the Code B1985?
- Faulty Lumbar Deflate Switch: The most common cause, involving internal electrical failure, corrosion, or mechanical damage preventing proper circuit closure or opening.
- Open Circuit in Wiring: A break or discontinuity in the electrical wiring harness connecting the lumbar deflate switch to the control module or the deflate actuator (solenoid/motor).
- Short Circuit to Ground or Voltage: The deflate circuit wiring may be chafed or damaged, causing it to contact the vehicle’s chassis ground or a positive voltage source.
- Corroded or Loose Electrical Connectors: Poor terminal tension or corrosion within the multi-pin connectors under the seat or at the control module can create high resistance or open circuits.
- Defective Lumbar Deflate Solenoid or Motor: An internal electrical failure within the actuator responsible for releasing air or retracting the lumbar mechanism can present as an open or short in the circuit.
- Faulty Seat Control Module (SCM) or Body Control Module (BCM): While less common, an internal fault within the controlling module’s driver circuit for the lumbar deflate function can trigger this code.
How to Diagnose and Troubleshoot
A systematic diagnostic approach is essential for accurately resolving DTC B1985:
- Retrieve All DTCs and Freeze Frame Data: Connect an OBD-II scanner to read all stored codes from the BCM/SCM. Note any other related B-codes or C-codes that might indicate a broader electrical issue. Analyze freeze frame data for insights into system conditions when the code was set.
- Visual Inspection: Carefully inspect the wiring harness under the affected seat, paying close attention to the lumbar deflate switch assembly and the wiring leading to the lumbar air pump/solenoid. Look for signs of chafing, pinching, corrosion, or disconnected connectors. Check for spilled liquids or debris around the switch.
- Verify Switch Operation with a Digital Multimeter (DMM):
- Access the electrical connector for the lumbar deflate switch. Refer to the OEM wiring diagram for pin identification.
- With the ignition off and the switch disconnected, use the DMM to measure continuity (ohms) across the switch terminals while pressing and releasing the deflate button. Expect a change in resistance or continuity between states (e.g., closed when pressed, open when released, or vice-versa, depending on switch type). An open circuit when continuity is expected, or constant continuity, indicates a faulty switch.
- Inspect Wiring for Open/Short Circuits:
- Using the OEM wiring diagram, identify the power, ground, and signal wires for the lumbar deflate circuit at both the switch and the lumbar actuator/control module.
- For Open Circuits: Perform a continuity test from one end of the wire to the other. Disconnect both ends of the suspect wire and measure resistance. A reading of greater than 5 ohms typically indicates an open circuit.
- For Short to Ground: Disconnect both ends of the suspect wire. Measure resistance between the wire and a known good chassis ground. A reading close to 0 ohms indicates a short to ground.
- For Short to Voltage: With the ignition on and relevant fuses installed, use the DMM to check for unexpected voltage on the signal wire when the switch is not activated.
- Test Lumbar Deflate Actuator (Solenoid/Motor):
- If the vehicle uses a separate solenoid or motor for deflate, disconnect its connector.
- Measure the internal resistance of the solenoid or motor using a DMM. Compare this reading to OEM specifications. An excessively high (open circuit) or very low (short circuit) resistance indicates an internal fault.
- If applicable, apply a fused 12V power and ground directly to the solenoid/motor (bypassing the control module) to verify its mechanical operation.
- Check Control Module Output: With an advanced diagnostic scanner capable of bi-directional control, attempt to command the lumbar deflate function. Monitor input signals from the switch and output signals to the actuator. If the module receives the correct switch input but fails to send an appropriate output signal to the actuator, the SCM/BCM may be faulty.
Recommended Repairs and Solutions
Once the root cause is identified through meticulous diagnosis, the following repairs are typically recommended:
- Replace the Lumbar Deflate Switch: If diagnostic steps confirm an internal fault within the switch, replacement is necessary. Ensure the replacement part is OEM or an equivalent quality aftermarket component.
- Repair or Replace Damaged Wiring: If an open circuit, short to ground, or short to voltage is found in the wiring harness, perform a professional wire repair using solder and heat-shrink tubing, or replace the entire affected section of the harness if damage is extensive.
- Clean and Secure Electrical Connectors: For corroded or loose connectors, clean the terminals with electrical contact cleaner and a small brush. Apply dielectric grease to protect against future corrosion and ensure a secure, positive connection. Repair or replace any bent or damaged terminals.
- Replace the Lumbar Deflate Solenoid or Motor: If the actuator is found to be faulty (e.g., incorrect resistance or no mechanical response), it must be replaced.
- Replace the Seat Control Module (SCM) or Body Control Module (BCM): This is a last resort, only after all other circuit components and wiring have been thoroughly tested and ruled out. Module replacement often requires specialized programming or configuration by an OEM-specific diagnostic tool.
Mechanic’s Tip: Always disconnect the vehicle’s battery before performing any electrical repairs under the seat to prevent accidental short circuits or airbag deployment. After repairs, clear all DTCs and perform a functional test of the lumbar system to confirm proper operation.