DTC B2559 indicates a detected condition where the Auxiliary A/C Blower Motor Relay Control Circuit is experiencing a short to battery voltage. This diagnostic trouble code is typically set by the Body Control Module (BCM), Powertrain Control Module (PCM), or a dedicated HVAC Control Module, depending on the vehicle’s electrical architecture. The control module monitors the voltage feedback on the specific circuit responsible for activating the auxiliary A/C blower motor relay. When the module commands the relay to be inactive (e.g., by providing a high-impedance state or pulling the circuit to ground for an ‘off’ state), it expects to see a specific voltage range, often near 0V or a specific pull-up/pull-down voltage. If the module detects a voltage significantly higher than expected, specifically at or near battery voltage (approximately 12V-14.5V), it registers this as an anomalous condition—a “short to battery”—and sets the B2559 code. This implies an unintended electrical path supplying constant power to the control circuit, which can lead to uncontrolled relay activation or prevent proper operation.

Common Symptoms

  • Auxiliary A/C Blower Motor Runs Continuously: The most common symptom, where the auxiliary blower motor operates even when the A/C system is commanded off, due to the relay being constantly energized.
  • Auxiliary A/C Blower Motor Inoperative: The short circuit may prevent the control module from properly grounding or controlling the relay coil, leading to no blower operation.
  • Rapid Battery Drain: If the auxiliary blower motor is running constantly, it can significantly discharge the vehicle’s battery over time, especially when the vehicle is off.
  • HVAC System Malfunction: General issues with the auxiliary (rear or secondary) climate control system, including inability to control fan speed or mode.
  • Blown Fuse: While less common for a control circuit short to battery, sustained overcurrent from the short could potentially blow a related fuse, though the code typically means power is still present on the circuit.

What Causes the Code B2559?

  • Damaged Wiring Harness: A chafed, cut, or pinched wire within the auxiliary A/C blower motor relay control circuit that has come into direct contact with a constant 12V power supply wire or an exposed B+ terminal.
  • Faulty Auxiliary A/C Blower Motor Relay: An internal short within the relay itself, where the switched high-current side (battery voltage) is internally bleeding or shorted to the control coil circuit, back-feeding battery voltage.
  • Corroded Electrical Connectors: Severe corrosion within a connector linking the control module to the relay, allowing a bridge between the control circuit terminal and an adjacent 12V power supply terminal.
  • Faulty Control Module (BCM/HVAC Module): Less common, but an internal short or component failure within the Body Control Module or dedicated HVAC Control Module could cause it to erroneously output battery voltage on the auxiliary blower motor relay control circuit when it should not.

How to Diagnose and Troubleshoot

Diagnosis of B2559 requires a systematic approach, often utilizing a digital multimeter (DMM) and vehicle-specific wiring diagrams.

  1. Visual Inspection: Begin with a thorough visual inspection of the auxiliary A/C system wiring harness, starting from the control module (BCM/HVAC module) to the auxiliary blower motor relay. Look for any signs of chafing, pinching, insulation damage, rodent damage, or corrosion, particularly where harnesses pass through bulkheads or body panels. Also, inspect the relay and its connector for signs of heat damage or corrosion.
  2. Retrieve Wiring Diagrams: Obtain the vehicle’s specific wiring diagrams for the auxiliary A/C system. Identify the control circuit wire(s) that connect the control module to the auxiliary A/C blower motor relay coil. Note the expected voltage states (e.g., ground to activate, 12V to deactivate) based on module command.
  3. Test Auxiliary Blower Motor Relay:
    • Disconnect the auxiliary A/C blower motor relay from its harness connector.
    • With the ignition OFF, use a DMM to measure voltage on the relay control circuit terminal (typically the low-current coil control wire from the BCM/HVAC module) at the harness connector, relative to chassis ground. A properly functioning circuit (with the relay disconnected and no command) should read near 0V.
    • Turn the ignition to the ON position (engine off) and ensure the auxiliary A/C system is commanded OFF. Re-measure the voltage on the control circuit terminal. If battery voltage (12V or higher) is present, it confirms a short to battery upstream of the relay.
  4. Isolate the Control Module: If battery voltage is detected at the relay connector (indicating a short upstream), proceed to disconnect the control module (BCM/HVAC module) that provides the control signal to the relay.
  • With the control module disconnected, re-measure the voltage at the auxiliary A/C blower motor relay control circuit terminal at the harness connector.
  • If the voltage now drops to 0V or significantly lower, the short is likely internal to the control module, or the module itself is supplying the erroneous voltage.
  • If the battery voltage persists, the short exists within the wiring harness between the disconnected control module and the relay connector.
  • Wiring Harness Continuity and Short Test: If the short is identified in the wiring harness:
    • Disconnect the vehicle battery to prevent further damage or accidental shorts.
    • Using the DMM in continuity mode, check for continuity between the identified control circuit wire (from the relay connector back towards the module) and known 12V B+ sources (e.g., adjacent power wires, battery positive terminal if accessible).
    • Carefully trace the harness, visually re-inspecting for points of contact with other wires or chassis components. Wiggle tests can sometimes help pinpoint intermittent shorts.
  • Test the Relay Itself: While the code points to the control circuit, it’s prudent to test the relay if there’s any suspicion. Apply fused 12V and ground to the coil terminals of the relay and check for continuity across the switch terminals. Ensure there’s no continuity across the switch when the coil is not energized, and verify the coil resistance is within specifications.
  • Recommended Repairs and Solutions

    • Repair or Replace Damaged Wiring: The most frequent solution involves locating the precise point of the short to battery in the wiring harness. Once identified, carefully repair the damaged wire using proper soldering techniques, heat-shrink tubing, and appropriate electrical tape. Ensure the repaired section is adequately protected and routed to prevent recurrence. If damage is extensive or involves multiple wires, replacing the entire affected harness section may be necessary.
    • Replace Auxiliary A/C Blower Motor Relay: If diagnostics confirm that the relay itself is internally shorted, causing the back-feed of battery voltage onto the control circuit, replace it with a new, OEM-equivalent relay.
    • Clean or Replace Corroded Connectors: If corrosion is found to be bridging terminals within a connector, thoroughly clean the affected terminals using electrical contact cleaner and a suitable brush. If corrosion is severe and has compromised terminal integrity, replace the connector shell and individual terminals as needed.
    • Replace Control Module (BCM/HVAC Module): Only consider replacing the control module as a last resort, after meticulously ruling out all external wiring and relay issues. If the module is confirmed to be internally shorted, causing it to incorrectly output battery voltage on the control circuit, it will need replacement. Be aware that many control modules require reprogramming or calibration after installation, which typically necessitates specialized diagnostic tools.
    • Mechanics’ Tips:
      • Always disconnect the vehicle’s battery before performing any electrical repairs to prevent accidental shorts or damage to sensitive electronic components.
      • Refer exclusively to the vehicle manufacturer’s wiring diagrams for accurate circuit identification and expected voltage values.
      • After any electrical repair, clear the DTCs from all relevant modules using an OBD-II scanner and perform a thorough functional test of the auxiliary A/C system to confirm the repair and ensure the code does not return.
      • Pay attention to areas where wiring harnesses are exposed to vibration, heat, or moisture, as these are common points for insulation breakdown and shorts.

    Leave a Reply

    Your email address will not be published. Required fields are marked *