What Does Code B1690 Mean?
DTC B1690 signifies an “Autolamp Delay Circuit Open” condition. This code specifically points to an electrical interruption or break within the circuit responsible for controlling the timed delay function of the automatic headlamp system. Modern vehicles are equipped with an autolamp system, primarily managed by the Body Control Module (BCM) or a dedicated lighting control module, which utilizes an ambient light sensor to automatically activate or deactivate the vehicle’s headlamps based on prevailing light conditions. The “delay” feature ensures that the headlamps do not immediately turn off or on in response to momentary changes in light (e.g., driving under an overpass) or, more commonly, provides a grace period (e.g., 30-60 seconds) after the ignition is switched off or doors are closed, allowing for illuminated entry/exit.
An “open circuit” indicates a complete interruption in the electrical path, preventing current flow through that specific part of the circuit. The BCM continuously monitors the electrical integrity of the autolamp delay circuit, often by measuring resistance or voltage drop across specific components or wiring segments. When the BCM detects an abnormally high resistance or a complete lack of continuity (infinite resistance) in the delay circuit, it interprets this as an open circuit condition and stores the B1690 diagnostic trouble code. This fault directly impacts the functionality and reliability of the vehicle’s automatic lighting subsystem.
Common Symptoms
- Autolamps fail to turn off after the ignition is switched off, remaining illuminated indefinitely.
- Autolamps turn off immediately upon ignition off, failing to provide the programmed delay.
- Autolamps may not activate automatically when ambient light levels dictate.
- Erratic or inconsistent autolamp behavior.
- The Malfunction Indicator Lamp (MIL) or a specific warning light related to exterior lighting may illuminate on the instrument cluster.
- Delayed entry/exit lighting features (e.g., “follow me home” lights) may be inoperative.
What Causes the Code B1690?
- Damaged or Corroded Wiring: A physical break, fraying, pinch, or severe corrosion in the wiring harness connecting the ambient light sensor, the autolamp switch, or the BCM to the headlamp relays, specifically within the delay circuit path.
- Faulty Ambient Light Sensor: The ambient light sensor itself may have an internal open circuit, preventing it from sending a proper signal to the BCM, or its internal resistance is out of specification.
- Corroded or Loose Electrical Connectors: Poor electrical contact at multi-pin connectors associated with the ambient light sensor, BCM, or headlamp relays, leading to an intermittent or complete open circuit.
- Faulty Body Control Module (BCM) / Lighting Control Module: An internal failure within the BCM or a dedicated lighting control module that is responsible for the autolamp delay function, such as a defective timing circuit or relay.
How to Diagnose and Troubleshoot
Diagnosis of B1690 requires a systematic approach, often involving a professional-grade OBD-II scanner, a digital multimeter (DMM), and access to vehicle-specific wiring diagrams.
- Initial Scan and Data Analysis:
- Connect an OBD-II scanner and retrieve all stored DTCs from the BCM, PCM, and any other relevant modules (e.g., Instrument Cluster, Lighting Control Module). Record freeze frame data, as it provides valuable insights into the conditions present when the fault was set.
- Note any other communication or electrical codes, as they might be related.
- Visual Inspection:
- Perform a thorough visual inspection of the entire autolamp system wiring harness, from the ambient light sensor (typically located on the dashboard, windshield, or instrument panel) to the BCM and the headlamp relay circuits. Look for obvious signs of damage, chafing, corrosion, or modifications.
- Inspect all connectors in the circuit for bent pins, corrosion, or loose connections. Pay close attention to the ambient light sensor connector and the main BCM connectors.
- Wiring Diagram Analysis:
- Obtain the specific vehicle’s wiring diagram for the autolamp system. Identify the power, ground, and signal wires for the ambient light sensor and the circuit path controlling the autolamp delay function. This is critical for accurate DMM testing.
- Digital Multimeter (DMM) Testing – Circuit Continuity:
- Isolate the circuit: Disconnect the ambient light sensor and the corresponding BCM connector. This prevents backfeeding voltage and allows for accurate continuity measurements.
- Test signal wires: Using the DMM set to resistance (ohms), check for continuity between the ambient light sensor signal wire terminal at its connector and the corresponding signal wire terminal at the BCM connector. An “OL” (open loop) reading or extremely high resistance indicates an open circuit in the wire.
- Test power and ground wires: Similarly, check continuity for the power supply wire (if applicable to the sensor) and the ground wire from their respective points to the BCM or chassis ground.
- Wiggle Test: While performing continuity tests, gently wiggle wiring harnesses and connectors to identify intermittent opens.
- Digital Multimeter (DMM) Testing – Voltage and Resistance (Sensor):
- Sensor Power/Ground: Reconnect the BCM (if necessary) and the ambient light sensor. With the ignition ON, verify proper reference voltage (e.g., 5V or 12V, as per specifications) at the ambient light sensor connector’s power supply pin, and verify a good ground connection.
- Sensor Output: If the ambient light sensor is a variable resistance type, disconnect it and test its resistance across its terminals. Expose it to varying light conditions and observe if its resistance changes according to manufacturer specifications. An internal open will show infinite resistance regardless of light.
- Component Isolation:
- If wiring and connectors test good, the fault lies within either the ambient light sensor or the BCM/lighting control module. Based on prior tests, replace the most likely faulty component. If the ambient light sensor is replaceable independently and its internal test suggests failure, replace it first.
Recommended Repairs and Solutions
The repair strategy for B1690 depends directly on the root cause identified during diagnosis:
- Repair or Replace Damaged Wiring: If an open circuit is found in the wiring harness, perform a professional wire repair. This involves cutting out the damaged section, splicing in a new section of wire of the correct gauge, and using appropriate crimp connectors, solder, and heat shrink tubing to ensure a durable and waterproof repair. Avoid simply taping over damaged insulation.
- Clean and Secure Connectors: If corrosion or looseness is found at connectors, use an approved electrical contact cleaner to remove corrosion. Ensure all pins are straight and make solid contact. Apply dielectric grease to prevent future corrosion. Replace any severely damaged connector shells or terminals.
- Replace Faulty Ambient Light Sensor: If diagnostic tests confirm an internal open or out-of-specification resistance in the ambient light sensor, replace it with a new OEM-equivalent part. Ensure the new sensor is correctly installed and its wiring harness is secured.
- Replace Body Control Module (BCM) / Lighting Control Module: If all other components (wiring, connectors, sensor) test good, and the autolamp delay circuit is confirmed to be an internal fault within the BCM or lighting control module, then module replacement is necessary. Be aware that BCM replacement often requires specialized programming and calibration using a factory-level diagnostic tool to integrate it with the vehicle’s other electronic systems. Always consult the vehicle manufacturer’s service procedures for module replacement.
- Clear Codes and Retest: After any repair, clear the DTCs using an OBD-II scanner. Perform several functional tests of the autolamp system in varying light conditions (e.g., drive into a dark garage, cover the sensor) to confirm the delay function operates correctly. Monitor for the re-illumination of the MIL or the recurrence of B1690.